首页|Numbering-up liquid-liquid systems in microfluidic reactors: A parametric study

Numbering-up liquid-liquid systems in microfluidic reactors: A parametric study

扫码查看
Present parametric study shows that the flowrate, number of channels, hydrodynamic resistances and phase ratio significantly affect the maldistribution in parallel microfluidic reactors (i.e., numbering-up). Especially the effect of flow rate and phase ratio has not been reported before. However, these findings are of a qualitative nature due to a high degree of variability between experiments. Additional experiments show that the stable point of operation easily shifts in the considered set-ups, explaining this variability. Therefore, a Multivariate Analysis of Variance (MANOVA) in SPSS is introduced to partially compensate for this variance and, also, manage the large data set that results from a parametric study. It is shown that introducing advanced statistical methods can provide additional insights and can further push the field of numbering-up.

Microfluidic reactorsNumbering-upHydrodynamic resistance networksMultivariate analysis of variance

Joren van Stee、Matthias Depotter、Koen Binnemans

展开 >

KU Leuven, Department of Chemical Engineering, Celestijnenlaan 200F, B-3001 Heverlee, Belgium

KU Leuven, Department of Chemistry, Celestijnenlaan 200F, B-3001 Heverlee, Belgium

2022

Chemical Engineering Research & Design