首页|Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270
Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270
扫码查看
点击上方二维码区域,可以放大扫码查看
原文链接
NSTL
Elsevier
This work analyses the influence of the Internal Heat Exchan ger (IHX) on the energy performance of a vapor compression cycle associated with a freezing cabinet using different R404A low-GWP alternatives. Among them, the refrigerants R454C (GPW100=146), R455A (GPW100=146), R468A (GPW100=146), R290 (GPW100=5) and R1270 (GPW100=1.8) have been tested in a horizontal freezing cabinet maintaining a product target temperature of -20°C at the heat rejection temperatures of 20, 30 and 40°C. The results from tests show that the use of the IHX reduces energy consumption in all scenarios without significantly increasing the compressor's discharge temperature. For a test period of 16 h, the refrigerants that offer better reductions are R404A and R1270, followed by R455A, R290, R454C and R468A. The maximum energy saving is rated to 9.2% at the heat rejection temperature of 40°C, demonstrating that the enhancement of the IHX is better as higher the heat rejection conditions are.
R1270R290R404aR454cR455AR468A
Cabello R.、Sanchez D.、Llopis R.、Andreu-Nacher A.、Calleja-Anta D.
展开 >
Jaume I University Dep. of Mechanical Engineering and Construction