Journal of Alloys and Compounds2022,Vol.92615.DOI:10.1016/j.jallcom.2022.166816

Temperature sensing with Er3+ doped Y2O3 nanoparticles operating within the 1st and 2nd biological window: The influence of particle size on the relative sensitivity of thermally decoupled levels

Laia A.S. Brandao-Silva A.C. Gomes M.A. Macedo Z.S. Valerio M.E.G. Rodrigues J.J. Alencar M.A.R.C.
Journal of Alloys and Compounds2022,Vol.92615.DOI:10.1016/j.jallcom.2022.166816

Temperature sensing with Er3+ doped Y2O3 nanoparticles operating within the 1st and 2nd biological window: The influence of particle size on the relative sensitivity of thermally decoupled levels

Laia A.S. 1Brandao-Silva A.C. 1Gomes M.A. 1Macedo Z.S. 1Valerio M.E.G. 1Rodrigues J.J. 1Alencar M.A.R.C.1
扫码查看

作者信息

  • 1. Universidade Federal de Sergipe (UFS) Departamento de Física
  • 折叠

Abstract

? 2022 Elsevier B.V.The luminescent properties of three nanocrystalline samples of Y2O3:Er3+ produced via PVA-assisted sol-gel route, with mean particle diameter of 21, 44 and 86 nm, were investigated aiming their application as optical temperature sensors within the first and second biological windows. Luminescence spectra were analyzed using three different wavelengths (532 nm, 660 nm and 800 nm) as excitation sources. The three samples exhibited up to four emission bands centered at 660 nm, 800 nm, 860 nm and 1000 nm, which were related to the 4F9/2 → 4I15/2, 4I9/2 → 4I15/2, 4S3/2 → 4I13/2 and 4I11/2 → 4I15/2 transitions of Er3+, respectively. Three luminescence intensity ratio (LIR) schemes associated with thermally decoupled levels were proposed and their dependence on ambient temperature was investigated, two for excitation at 660 nm and one for excitation at 800 nm. In all the three cases, excitation and emission wavelengths were within the first or second biological window. Relative sensitivities of up to 2.02 ± 0.06% K?1 were obtained, with good repeatability and reproducibility and with temperature uncertainties below 1 K. The influence of particle size on luminescence intensity and sensor sensitivity was also presented and discussed, considering the potential applications. The results showed that particle size can affect the sensitivity of each LIR differently depending on the phonon-assisted processes involved.

Key words

Biological application/Luminescence intensity ratio of non-thermally coupled levels/Luminescent nanothermometry

引用本文复制引用

出版年

2022
Journal of Alloys and Compounds

Journal of Alloys and Compounds

EISCI
ISSN:0925-8388
被引量6
参考文献量63
段落导航相关论文