首页|Failure analysis and improvement measures for crankshaft connecting rod of refrigerator compressor
Failure analysis and improvement measures for crankshaft connecting rod of refrigerator compressor
扫码查看
点击上方二维码区域,可以放大扫码查看
原文链接
NSTL
Elsevier
With the improvement of family life quality and the implementation of energy-saving green household appliances, the volume of refrigerator increases rapidly and the energy efficiency ratio continues to decrease. However, the compressor size is required to be smaller, and the startup and shutdown are more frequent, which aggravates the wear of crankshaft connecting rod. Here, the failure compressor (300 ppm) provided by the manufacturer was disassembled and analyzed. The results showed that there were abrasive wear and adhesive wear on the surface of crankshaft and connecting rod. The source of solid particles in compressor was further analyzed, and the process control measures were proposed. In addition, combined with its failure mechanism and pro-duction process, the crankshaft surface composite treatment process was designed and bench test was carried out, which shows excellent anti-wear and self-lubricating performance.