首页|Early Experience With a Novel Dissection-Specific Stent-Graft to Prevent Distal Stent-Graft-Induced New Entry Tears After Thoracic Endovascular Repair of Chronic Type B Aortic Dissections

Early Experience With a Novel Dissection-Specific Stent-Graft to Prevent Distal Stent-Graft-Induced New Entry Tears After Thoracic Endovascular Repair of Chronic Type B Aortic Dissections

扫码查看
? 2021 The AuthorsBackground: The aim was to report short and mid-term outcomes of a novel, investigational, dissection-specific stent-graft (DSSG), specifically designed to address the features of chronic type B aortic dissection (CTBAD) and reduce the risk of distal stent-graft-induced new entry tears (dSINE). Materials and Methods: A retrospective single center cohort study of all patients undergoing TEVAR with the DSSG for CTBAD from January 1, 2017 to January 31, 2020. The DSSG, which is a modified stent-graft based on the Cook Zenith Alpha Thoracic platform, has no proximal barbs, and a customized longer body length with substantial taper. The second and third distal Z-stents are sited internally to avoid any contact of the metal skeleton with the dissection membrane and have reduced radial force, while the most distal stent was removed creating a distal 30 mm unsupported Dacron graft. Results: Sixteen patients (13 males, 3 females) with a median age of 66 years (range 31–79 years) underwent elective TEVAR of CTBAD using the DSSG. Six patients (38%) had an underlying connective tissue disorder. The median tapering was 10 mm (range 4 mm–21 mm) and median length 270 mm (range 210–380 mm). Technical success was achieved in all but one case (96%). One patient died within 30 days, due to retrograde type A dissection with cardiac tamponade. The 30-day rate of stroke, spinal cord ischemia, and re-interventions was 0%. After median imaging follow-up time of 17 months (range 1–31 months), one patient developed a dSINE 4 months after the index procedure. After median survival follow-up of 23 months (range 2–35 months), one late death occurred due to traumatic brain injury, while no aortic-related death occurred during follow-up. Complete false lumen (FL) thrombosis was achieved in 9 patients while the remaining 6 showed partial FL thrombosis. No instances of diameter increase at the level oftreated aortic segment were noted with serial measurements showing either stable (n = 7) or decreased (n = 8) maximal transverse diameter. Conclusions: Use of a novel DSSG with low radial force for TEVAR in the setting of CTBAD is safe and feasible. This early real-world experience shows promising mid-term effectiveness with low rates of dSINE or unplanned re-interventions and satisfactory aortic remodeling during follow-up. Longer follow-up is needed, however, before any firm conclusions can be drawn.

Aortic dissectionEntry tearStent-graftThoracic endovascular aortic repair

Burdess A.、D'Oria M.、Mani K.、Tegler G.、Lindstrom D.、Mogensen J.、Kolbel T.、Wanhainen A.

展开 >

Department of Surgical Sciences Vascular Surgery Uppsala University

Division of Vascular and Endovascular Surgery Cardiovascular Department University Hospital of

Cook Medical Bjaeverskov

German Aortic Center Department of Vascular Medicine University Heart and Vascular Center

展开 >

2022

Annals of vascular surgery

Annals of vascular surgery

ISTP
ISSN:0890-5096
年,卷(期):2022.81
  • 5
  • 29