首页|Comparative study of cooling performance for portable cold storage box using phase change medium

Comparative study of cooling performance for portable cold storage box using phase change medium

扫码查看
The present study numerically investigates the cooling performance of portable cold storage boxes using phase change material (PCM) for safe and secure transportation of vaccines under a controlled temperature range of -55 degrees C to -40 degrees C at different ambient conditions. A suitable PCM (SP-50) is identified to comply with the temperature requirement of the cold storage box and a comparative study has been performed between a cuboid and cylindrical configuration having the same volume of the box and PCM. Temporal variation of temperature and liquid fraction during phase change of PCM are demonstrated with the help of CFD analysis. The inside temperature of the cylindrical configuration of the box is found to be 4.03% lower than the cuboid box after 17hrs of cooling duration for an ambient temperature of 45 degrees C. Cooling efficiency and cooling duration of the cylindrical configuration is 8.7% and 20.4% more than the cuboid one respectively at the ambient temperature of 30 degrees C. The relative dominance between convection and radiation heat transfer is evaluated at different surfaces for both configurations.

Phase change mediumVaccine storage boxLiquid fractionEnthalpy-porosityCooling efficiencyCHAIN

Ray, Alok K.、Singh, Sumer、Rakshit, Dibakar、Udayraj

展开 >

Indian Inst Technol

Indian Inst Technol Bhilai

2022

Thermal science and engineering progress

Thermal science and engineering progress

SCI
ISSN:2451-9049
年,卷(期):2022.27
  • 14
  • 26