首页|Microstructure and stress corrosion cracking behavior of Alloy 690TT steam generator tubes with internal bulge defect

Microstructure and stress corrosion cracking behavior of Alloy 690TT steam generator tubes with internal bulge defect

扫码查看
S C Alloy 690TT tube samples with different sizes of internal bulge defect (IBD) are prepared by actual hydraulic tube expansion in field and their microstructure and stress corrosion cracking (SCC) behavior are studied in detail. The hardening level and residual strain increase as moving from the original area of the tube to the bulged area, and so as for the increasing of deformation sizes. Corrosion test with a duration of 20 0 0 h shows that the IBD area has higher SCC sensitivity than the original tube. In addition, IBD with larger size is more sensitive to SCC. (c) 2022 Elsevier B.V. All rights reserved.

Alloy 690TTTube expansionInternal bulge defectStress corrosion crackingIntergranular corrosionHigh temperature corrosionHEAT-AFFECTED ZONEHIGH-TEMPERATUREARTIFICIAL DEFECTSGRAIN-BOUNDARIESSECONDARY WATERTTDEFORMATIONRESISTANCEPWSCC

Ming, Hongliang、Wu, Bin、Zhang, Zhiming、Meng, Fanjiang、He, Guangqing、Wang, Jianqiu、Han, En-Hou

展开 >

Chinese Acad Sci

Inst Corros Sci & Technol

Shanghai Nucl Engn Res & Design Inst Ltd Co

Fudan Univ

展开 >

2022

Journal of Nuclear Materials

Journal of Nuclear Materials

EISCI
ISSN:0022-3115
年,卷(期):2022.563
  • 7
  • 47