首页|Stress corrosion cracking of U tube heat exchanger used for low pressure steam generation in a hydrogen unit of petroleum refinery

Stress corrosion cracking of U tube heat exchanger used for low pressure steam generation in a hydrogen unit of petroleum refinery

扫码查看
? 2022 Elsevier LtdThe reformer effluent is serially cooled down to produce hydrogen in the hydrogen unit of an oil refinery. The process heat from effluent is effectively utilized for low pressure steam generation using heat exchanger. The exchanger shell and tube side fluids were boiler feed water and process gas, respectively. Several tubes of this heat exchanger were failed especially within tube sheet after 4 years of useful service. Therefore, failed exchanger tube was subjected to engineering failure analysis to determine the cause of failure. Initially visual inspection was conducted using videoscopy in heat exchanger dry condition and evidenced circumferential crack. Subsequently, all failed tubes were separated from U tube bundle. Selected tube was subjected to visual inspection, dye penetrant and dimensional measurement. No evidence of visual deformation and thickness loss observed in the failed tube. Further investigated tube was subjected to chemical analysis and confirmed the required metallurgy as per design specification. The fracture surface was subjected to elemental analysis, fractographic, metallographic and hardness investigations. The micro hardness of an exchanger tube at failure location was higher than specified hardness value. Investigation also revealed that exchanger tubes were expanded from tube inner surface to establish tube to tube sheet joint according to specified design drawing. Tube expansion was done prior to start of service and attributed to residual stress within tube material. The results revealed that presence of chloride in the accumulated deposits within tube to tube sheet joint favored conducive environment for chloride stress corrosion cracking. Recommendations were suggested for failure prevention. Achievement in this paper may supplement the similar heat exchanger tube failure database and mitigation of failure will be possible by good engineering practices.

Chloride stress corrosion crackingCrevice locationHeat exchangerPitting corrosionTEMA/ASME codeTube to tube sheet interface

Subramanian C.、Ghosh D.、Reddy D.S.、Natarajan R.、Velavan S.P.

展开 >

NDT & Metallurgy Group Central Mechanical Engineering Research Institute-CSIR

Department of Chemical Sciences Indian Institute of Science Education and Research (IISER)

Chennai Petroleum Corporation Limited (A Group Company Indian Oil Corporation)

2022

Engineering failure analysis

Engineering failure analysis

EISCI
ISSN:1350-6307
年,卷(期):2022.137
  • 8