首页|Performance characteristics of a small scale cyclone separator operated in different flow regimes
Performance characteristics of a small scale cyclone separator operated in different flow regimes
扫码查看
点击上方二维码区域,可以放大扫码查看
原文链接
NSTL
Elsevier
The flow pattern, cyclone pressure drop and particle penetration through a sampling cyclone have been studied at a wide range of flow rate 0.22-7.54 LPM using the LES simulations that have been validated based on experimental penetration data. The cyclone performance has been described by three dimensionless characteristics, the Euler number Eu-out(stat) , cut-size psi(50) and slope of the transformed penetration curve ?1. Three main flow regimes and four sub-regimes have been revealed. The effects of the flow rate (Reynolds number) on the dimensionless cyclone performance characteristics have been described and a one-term power series model has been proposed. Additionally, the effect of the aspiration efficiency on the cyclone cut-size has been determined.