Applied thermal engineering2022,Vol.21520.DOI:10.1016/j.applthermaleng.2022.118998

Exergetic analysis of the humidification-dehumidificationdesalination cycle involving variation in top temperature

Sidra Zahid Shafiq-Ur-Rehman Qureshi Waqar Ahmed Khan Umer Zahid
Applied thermal engineering2022,Vol.21520.DOI:10.1016/j.applthermaleng.2022.118998

Exergetic analysis of the humidification-dehumidificationdesalination cycle involving variation in top temperature

Sidra Zahid 1Shafiq-Ur-Rehman Qureshi 1Waqar Ahmed Khan 1Umer Zahid2
扫码查看

作者信息

  • 1. Department of Engineering Sciences, PN Engineering College, National University of Sciences and Technology, PNS Jauhar
  • 2. Department of Mechanical and Aerospace Engineering, Politecnico di Torino
  • 折叠

Abstract

Saline water desalination is attaining a prime focus to meet the challenges of water scarcity in the developing countries. Solar energy could be effectively utilized for desalinating the saline/sea water. In this respect, humidification dehumidification (HDH) cycle could prove as a promising solar driven desalination technology. In this paper, exergy analysis of single extraction air heated and water heated HDH desalination cycles are examined in detail. The top temperature and extraction rate parameters are considered crucial for any typical single extraction HDH cycle. Analysis of the effects of varying top cyclic temperature keeping fixed extraction/injection rate of 70% water/air stream is carried out. The top temperature is varied between 60℃-80℃ range. For the air heated air extraction cycle, total exergy destroyed is higher at lower top temperatures, resulting in lower exergetic efficiency. A similar trend is also followed by the air heated water extraction cycle for the top temperatures ranging up to 70℃. The total exergy destroyed registered an increase above 70℃ because of the significant rise in exergy destruction for the heater component. In the water heated cycle with water/air extraction, exergy destroyed decreases at lower top temperatures, thereby yielding higher exergetic efficiencies. For each HDH cycle configuration, correlation between the gain output ratio (GOR) and exergetic efficiency is additionally obtained. The results revealed that at the given top temperature, sub-component effectiveness, mass flow rate ratio and bottom temperature parameters, the GOR increases with the exergetic efficiency of the cycle.

Key words

Humidification dehumidification cycle/Exergetic efficiency/Solar desalination/Top temperature/Gain-output ratio