首页|Reliability of acicular grindable thermocouples for transient temperature measurements at sliding contacts

Reliability of acicular grindable thermocouples for transient temperature measurements at sliding contacts

扫码查看
? 2022 The AuthorsAcicular grindable thermocouples represent an interesting and prospective technique of temperature measurements at sliding contacts. This study aimed at the investigation of their reliability and accuracy as applied to the friction materials of various classes in contact with steel. The tests were conducted on a pin-on-disc tribometer under stationary and transient regimes. The experimental results were validated by comparing the temperature data obtained by the acicular thermocouple, conventional thermocouples and infrared thermography. It was found that the measurements conducted with the acicular thermocouples are test-retest reliable for copper and a brake pads material, whereas they are not reliable for a polyamide. The temperature rise measured with the acicular thermocouple deviates from that registered by infrared thermography by 7–15% for copper and 10–19% for the brake pads material.

Contact temperatureGrindable thermocoupleMeasurement reliabilitySliding contactTemperature measurement

Nosko O.、Tsybrii Y.、Tarasiuk W.、Nosko A.

展开 >

Gdansk University of Technology Faculty of Mechanical Engineering and Ship Technology

Bialystok University of Technology Faculty of Mechanical Engineering

Bauman Moscow State Technical University Department of Lifting and Transport Systems

2022

Measurement

Measurement

SCI
ISSN:0263-2241
年,卷(期):2022.196
  • 2