首页|Alternating prestress monitoring of steel strands based on the magnetoelastic inductance method
Alternating prestress monitoring of steel strands based on the magnetoelastic inductance method
扫码查看
点击上方二维码区域,可以放大扫码查看
原文链接
NSTL
Elsevier
Alternating prestress is difficult to measure. By analyzing the inverse magnetostriction effect and the magnetic hysteresis, a theoretical model was established to describe the prestress-inductance relationship. The results of the prestress monitoring experiment showed that the inductance was influenced by the irreversible magnetization, the plastic deformation, and the hysteresis effect. Keeping the stress range constant, the inductance range was unaffected by the number of load cycles. The inductance can be used to judge whether the prestress is reasonable. The parabolic fitting method was employed to establish the mapping from the inductance to the prestress. When the stress range was 10% design prestress or 20% design prestress, the prestress monitoring error, less than 12.56% or 18.77%, was close to the magnetoelastic method and the frequency-based method. Based on the proposed calculation method, the MI method could monitor the alternating prestress of steel strands.