首页|Enhanced pool boiling of propane on horizontal U-shaped tubes in a large-scale confined space

Enhanced pool boiling of propane on horizontal U-shaped tubes in a large-scale confined space

扫码查看
This paper aims to experimentally investigate the heat transfer characteristics of pool boiling on horizontal U-shaped tubes in a large-scale confined space. The saturation temperature ranges from 20 to 40 degrees C and the heat flux varies from 2.5 to 10.5 kWm(-2). Two types of tubes with an outside diameter of 19.05 mm are tested: a smooth tube and a fin-enhanced tube with 0.4 mm fin height, 1220 fpm (fins per meter) and a 0.12 mm fin gap. The tubes are made of titanium with a length of 1165 mm. In case of pool boiling, the heat transfer coefficient for the tested tubes increases with increasing saturation temperature and heat flux. The fin-enhanced tube facilitates the bubble nucleation with the heat transfer coefficient enhancement factor varying in the range of 1.25 similar to 2.28. Furthermore, the experimental heat transfer coefficients are compared with four correlations obtained in the open literature. R-J correlation and Copper correlation are found to be the optimum correlation for the smooth tube and the enhanced tube with the mean relative error of 10.93% and 11.48%, respectively. Findings from this study can supply a fundamental basis for validation and improvement propane heat transfer performances for the intermediate fluid vaporizer (IFV) engineering design.

PropanePool boilingHeat transfer coefficientFin-enhanced tubeLarge-scale confined spaceCorrelation comparisonINTERMEDIATE FLUID VAPORIZERHEAT-TRANSFER COEFFICIENTSTHERMAL DESIGNREFRIGERANTSSURFACE

Tian, Zhen、Wang, Feng、Gu, Bo、Zhang, Yuan、Gao, Wenzhong

展开 >

Shanghai Maritime Univ

Shanghai Jiao Tong Univ

2022

International Journal of Refrigeration

International Journal of Refrigeration

EISCI
ISSN:0140-7007
年,卷(期):2022.133
  • 2
  • 37