首页|Failure analysis of platen superheater tube, water wall tube, and sealpot plate: A case study from electricity power plant in indonesia

Failure analysis of platen superheater tube, water wall tube, and sealpot plate: A case study from electricity power plant in indonesia

扫码查看
? 2022 Elsevier LtdFailure analysis of the platen superheater tube, water wall tube, and sealpot plate were investigated in the present study. To examine the causes of failure, various techniques, including visual examination, chemical composition test using Optical Emission Spectrometry (OES), fracture surface examination using Scanning Electron Microscope (SEM), tensile test, hardness test, and metallography test were carried out. Samples average thickness were 6.46 mm, 6.23 mm, and 9.29 mm, respectively. The chemical composition of the platen superheater tube, water wall tube, and sealpot plate material samples was not conforming to the standard material. The eroded tube surface contributed to the failure mechanism that caused by escaping steam in high velocity which leading to another leakage. This escaping steam also damages the adjacent surface by 'steam cutting' mode and erosion in both platen superheater tube and water wall tube.

ErosionLeakagePlaten superheater tubeSealpot plateWater wall tube

Dini Hariyanto S.、Hozaifa Hasan W.、Adi Himarosa R.、Akhsin Muflikhun M.

展开 >

Mechanical Engineering Department IST AKPRIND

Mechanical and Industrial Engineering Department Gadjah Mada University

Mechanical Engineering Department Universitas Muhammadiyah Yogyakarta

2022

Engineering failure analysis

Engineering failure analysis

EISCI
ISSN:1350-6307
年,卷(期):2022.135
  • 11
  • 31