Applied thermal engineering2022,Vol.21011.DOI:10.1016/j.applthermaleng.2022.118343

Experimental performance of a three-fluid desiccant contactor using a novel ionic liquid

Varela, Richard Jayson Giannetti, Niccolo Saito, Kiyoshi Wang, Xinming Nakayama, Hiroshi
Applied thermal engineering2022,Vol.21011.DOI:10.1016/j.applthermaleng.2022.118343

Experimental performance of a three-fluid desiccant contactor using a novel ionic liquid

Varela, Richard Jayson 1Giannetti, Niccolo 1Saito, Kiyoshi 1Wang, Xinming 2Nakayama, Hiroshi3
扫码查看

作者信息

  • 1. Waseda Univ
  • 2. Evonik Japan Co Ltd
  • 3. Chubu Elect Power Co Inc
  • 折叠

Abstract

The experimental performance of a new three-fluid fin-tube contactor using a novel ionic liquid desiccant solution is investigated and compared with those of an adiabatic packed bed contactor with LiCl solution for liquid desiccant air conditioning system applications. Owing to the compatibility of the ionic liquid solution with aluminum, a fin-tube contactor is manufactured to exploit internal cooling from a third fluid. The results indicate the superior dehumidification performance of the fin-tube contactor, which yielded an outlet air humidity ratio of 10.5 g(w).kg(da)(-1) at a solution mass flux of 3.06 kg.m(-2).s(-1), as compared to a similar humidity ratio at a solution mass flux of 4.98 kg.m(-2).s(-1) achieved by the packed bed contactor. In terms of cooling performance, the outlet air temperature of the fin-tube contactor is 21.9 degrees C, which is lower than that of the packed bed contactor even at its highest solution mass flux. This indicates that the cooling performance of the fin-tube contactor has minimal dependence on the solution mass flux in achieving cooling effect, owing to the cooling medium flowing inside the tubes. Relatively lower solution pumping power than that of the packed bed contactor can be expected from the fin-tube contactor, in addition to the ability to achieve comfortable and hygienic indoor air at a cooling medium temperature of 17 degrees C or higher, the ionic liquid desiccant and three-fluid fin-tube contactor pair for liquid desiccant air conditioning system is elevated a step higher as an alternative to vapor compression air conditioning system.

Key words

Ionic liquid/Three-fluid desiccant contactor/Experimental performance/Performance comparison/Energy conservation/AIR-CONDITIONING SYSTEM/MASS-TRANSFER COEFFICIENTS/THERMOPHYSICAL PROPERTIES/DEHUMIDIFICATION/DEHUMIDIFIER/REGENERATOR/ABSORPTION/REMOVAL

引用本文复制引用

出版年

2022
Applied thermal engineering

Applied thermal engineering

EISCI
ISSN:1359-4311
被引量13
参考文献量38
段落导航相关论文