首页|ata acquisition and control system for lead-bismuth loop KYLIN-II-M

ata acquisition and control system for lead-bismuth loop KYLIN-II-M

扫码查看
mong different heavy liquid metals (HLMs), lead-bismuth eutectic (LBE) is considered at present as a potential candidate for the coolant of new generation fast reactors (critical and subcritical) and for liquid spallation neutron sources and accelerator driven systems (ADS). A high temperature liquid LBE loop, KYLIN-II-M, has been built to study the characteristics of corrosion and fluidity of LBE at the Institute of Nuclear Energy Safety Technology. However, due to the sensors and execution components of the loop work at high temperatures and in severely corrosive environments, the reliability and security of the data acquisition and control system (DACS) of KYLIN-II-M face challenges during the loop operation. In order to meet the urgent needs for KYLIN-II-M’s long-term stable operation, a virtualization and redundancy control system has been developed. The onsite operation result shows that the DACS is stable and reliable. In this paper, the experimental results are described in detail.
ata acquisition and control system for lead-bismuth loop KYLIN-II-M

Lead-bismuth eutecticKYLIN-II-Mata acquisition and control systemRedundancy control system

YAO Chuan-Ming、HE Jian、ZHU Zhi-Qiang、LI Yang、HUANG Qun-Ying

展开 >

原子能技术(核反应堆工程)

自动化技术、计算机技术(自动化技术、自动化技术设备)

原子能技术(粒子探测技术、辐射探测技术、核仪器仪表)

Lead-bismuth eutectic KYLIN-II-M ata acquisition and control system Redundancy control system

首发时间:2023-06-18