Eman S. ElzanfalyAhmed S. SaadAbd Elaziz B. Abd Elaleem
382-385页
查看更多>>摘要:A new simple spectrophotometric method was developed for the simultaneous determination of drugs with interfering spectra in binary mixtures without previous separation. The new method is based on a simple modification for the ratio subtraction method. This modification enabled wider range of application. The proposed ratio difference method was applied for the determination of brimonidine and timolol in laboratory prepared mixtures with mean percentage recoveries 100.40±2.29 and 101.23± 1.30 respectively, and in their pharmaceutical formulation with mean percentage recoveries 101.08±0.44 and 100.66±0.52 respectively. The suggested ratio difference method was validated according to USP guidelines and can be applied for routine aualitv control testing.
查看更多>>摘要:The purpose of this study was to investigate the hydrolyzation of aspirin during the process of dissolution testing for aspirin delayed-release tablets. Hydrolysis product of salicylic acid can result in adverse effects and affect the determination of dissolution rate assaying. In this study, the technique of differential spectra was employed, which made it possible to monitor the dissolution testing in situ. The results showed that the hydrolyzation of aspirin made the percentage of salicylic acid exceed the limit of free salicylic acid (4.0), and the hydrolyzation may affect the quality detection of aspirin delayed-release tablets.
查看更多>>摘要:A rapid and simple high performance liquid chromatography (HPLC) mcthod wiih a UV detection (241 nm) was developed and validated for estimation of eplerenone from spiked human plasma. The analyte and the internal standard (valdecoxib) were extracted with a mixture of dichloromethane and diethyl ether. The chromatographic separation was performed on a HiQSil C-18HS column (250 mm × 4.6 mm, 5 um) with a mobile phase consisting of acetonitrile:water (50:50, v/v) at flow rate of 1 mL/min. The calibration curve was linear in the range 100 3200 ng/mL and the heteroscedasticity was minimized by using weighted least squares regression with weighting factor I/X.
查看更多>>摘要:The GCMS-QP2010 Ultra is our most advanced gas chromatograph mass spectrometer. Descended from the GCMS-QP2010 Plus, it features best-in-class scan speed and sensitivity. A newly designed and patented technology called ASSPTM (Advanced Scan Speed Protocol) allows this GC-MS to scan at 20,000 u/sec without sensitivity loss or spectral distortion.