摘要
[目的]建立可同时测定豆类食品中几种有害重金属元素的分析方法。[方法]利用硝酸-过氧化氢体系高压消解豆类样品,建立了电感耦合等离子体质谱法( ICP-MS)同时测定豆类中Pb、Cd、Tl、As、Cr、Ni 6种重金属元素的分析方法。应用碰撞反应池技术(动能甄别)消除多原子离子等质谱干扰,以Ge、In、Bi和Sc为内标元素校正质谱分析中的基体效应。[结果]在最佳的试验条件下,各元素的检出限在0.11~18.40μg/kg,相关系数均大于0.999。方法应用于国家有证标准物质(GBW10013)测定,测定值均在参考值范围内。[结论]该研究建立的方法灵敏度高、检出限低、准确度高,且操作简单快速,可应用于豆类食品中重金属元素的批量分析。
Abstract
Objective] The aim was to establish analysis method for simultaneously determining several harmful heavy metal elements in legume food.[ Method] A novel method has been developed for the determination of trace elements,including Pb,Cd,Tl,As,Cr and Ni in legume food by inductively coupled plasma mass spectrometry (ICP-MS).Samples were dissolved in a mixture of HNO3 and H2O2 in sealed vessels by using a ov-en.The use of octopole reaction system( Kinetic energy discrimination) eliminated the interference of polyatomic ions dramatically,Ge,In,Bi and Sc were selected as the internal standard element to overcome non-spectroscopic interference.[ Result] Under the optimal conditions,the detection limits were in the range of 0.11-18.40 μg/kg with elemental correlation coefficients over 0.999.The method was tested using national standard substance(GBW10013) and the resultswere in good agreement with the recommended values.[Conclusion] The method has the advantages of high sensitive,low detection limit,high accuracy,simplicity and rapidness,and can be used for batch analysis of legume food.