首页|1例假性低钠血症的实验室分析

1例假性低钠血症的实验室分析

扫码查看
目的 通过对1例低钠血症的实验室分析加强临床对假性低钠血症的认识.方法 结合患者的疾病史,实验室检查结果,分析方法学检测原理以及更换方法学检测对造成患者低钠血症的原因进行分析.结果 患者高蛋白血症干扰间接离子选择电极法对血钠的检测,造成血钠结果假性偏低.选用直接法的血气分析后血钠正常.结论 高蛋白血症人群使用全自动生化分析仪检测血钠结果会造成假性偏低,可更换直接法检测,以免造成误诊.
The Laboratory Analysis of a Case of Pseudohyponatremia
Objective To improve the current clinical understanding of pseudohyponatremia through laboratory analysis of a case of hyponatremia.Methods The potential causes of hyponatremia were investigated based on the patients'disease history,laboratory test results,analytical methodology and changes of the methodology.Results Patient's hyperproteinemia interfered with the detection of sodium by indirect ion selective electrode,resulting in low false results of sodium results.Blood natrium level was normal after direct blood gas analysis.Conclusion Usage of automatic biochemical analyzer to detect sodium in hyperproteinemia could result in low falsity,suggesting that a direct method should be used to avoid misdiagnosis.

False low sodiumIndirect ion selective electrode methodDirect methodBlood gas analysis

罗盈、姚亚男、陈敏静、李文敏、邸玉玮

展开 >

南方医科大学附属广东省人民医院(广东省医学科学院)检验科,广东广州 510000

假性低钠 间接离子选择电极法 直接法 血气分析

国家自然科学基金

82202627

2024

标记免疫分析与临床
中国同辐股份有限公司

标记免疫分析与临床

CSTPCD
影响因子:0.978
ISSN:1006-1703
年,卷(期):2024.31(5)
  • 10