首页|液相色谱串联质谱法检测脂溶性维生素模拟校准品基质的选择和评价

液相色谱串联质谱法检测脂溶性维生素模拟校准品基质的选择和评价

扫码查看
目的 选择和评价液相色谱串联质谱法检测脂溶性维生素标准曲线的模拟基质.方法 采用纯甲醇、4%牛血清白蛋白(BSA)作为模拟基质,配制脂溶性维生素的标准曲线.通过线性实验、正确度实验、基质效应实验,对模拟基质进行评价.采用两条标准曲线分别对临床44例血清样本进行定量,依据CLSI EP9-A3文件,对结果进行比对.结果 以纯甲醇为基质,维生素A(VA)、25-羟基维生素D3[25(OH)D3]、25-羟基维生素D2[25(OH)D2]、维生素E(α-VE)对应标准曲线的相关系数分别为0.999、0.997、0.997、0.999,加标回收率为90.0%~110.1%,相对基质效应为-7.40%~7.90%.以4%BSA为基质,VA、25(OH)D3、25(OH)D2、α-VE对应标准曲线的相关系数分别为0.999、0.997、0.997、0.999,加标回收率为91.1%~111.2%,相对基质效应为-8.84%~7.60%.两条标准曲线对44例临床样本的定量结果进行线性拟合,VA、25(OH)D、α-VE 对应的 Passing-Baklok 回归方程分别为 Y=0.9083X-3.7026、Y=1.0406X-3.0114、Y=1.018X-72.786,医学决定水平处的预估偏移均在可接受范围内.结论 纯甲醇和4%BSA均可作为脂溶性维生素校准品的模拟基质,各实验室应评估模拟基质的适用性,以确保临床检测结果的准确性.
The Selection and Evaluation of Matrix for the Determination of Fat-soluble Vitamin Calibrators by Liquid Chromatography Tandem Mass Spectrometry
Objective To select and evaluate a simulated substrate for the determination of standard curves of fat-soluble vitamins by liquid chromatography-tandem mass spectrometry.Methods The standard curve of fat-soluble vitamin was prepared by using pure methanol and 4%bovine serum albumin(BSA)as simulated matrix.The simulated matrix was evaluated by linear experiment,accuracy evaluation experiment and matrix effect mixed experiment.Two standard curves were drawn to quantify serum samples from 44 clinical cases and the results were compared according to CLSI EP9-A3 file.Results Using pure methanol as the substrate,the correlation coefficients of the corresponding standard curves of vitamin A(VA),25-hydroxyvitamin D3[25(OH)D3],25-hydroxyvitamin D2[25(OH)D2]and vitamin E(α-VE)were 0.999,0.997,and 0.999,respectively,while the recoveries were 90.0%-110.1%.The relative matrix effect ranges from-7.40%to 7.90%.Using 4%BSA as matrix,the correlation coefficients of VA,25(OH)D3,25(OH)D2 and α-VE corresponding standard curves were 0.999,0.997,0.997,and 0.999,respectively.The recoveries were 91.1%-111.2%and the relative matrix effects were-8.84%-7.60%.Two standard curves were applied to linearly fit the quantitative results of 44 clinical samples.The developed regression equations of VA,25(OH)D and α-VE were as follows:Y=0.9083X-3.7026,Y=1.0406X-3.0114,and Y=1.018X-72.786,respectively.The estimated deviations at medically determined levels were within acceptable limits.Conclusion Both pure methanol and 4%BSA can be used as simulated substrates for fat-soluble vitamin calibrators.The applicability of simulated substrates should be evaluated in laboratories to ensure the accuracy of clinical test results.

Fat-soluble vitaminSimulated matrixLiquid chromatography tandem mass spectrometry

李敏、孙江漫、孟祥兆、赵光轮、韩玉霞、于洪远、李会强

展开 >

北京航天总医院检验科,北京 100076

天津医科大学医学检验学院,天津 300203

脂溶性维生素 模拟基质 液相色谱串联质谱

2024

标记免疫分析与临床
中国同辐股份有限公司

标记免疫分析与临床

CSTPCD
影响因子:0.978
ISSN:1006-1703
年,卷(期):2024.31(11)