中国医学科学杂志(英文版)2024,Vol.39Issue(2) :122-130.DOI:10.24920/004307

Diagnostic Accuracy of Computerized Bowel Sound Analysis with Non-Invasive Devices for Irritable Bowel Syndrome:A Systematic Review and Meta-Analysis

Xia-Xiao Yan Yue-Lun Zhang Yu-Pei Zhang Ying-Yun Yang Dong Wu
中国医学科学杂志(英文版)2024,Vol.39Issue(2) :122-130.DOI:10.24920/004307

Diagnostic Accuracy of Computerized Bowel Sound Analysis with Non-Invasive Devices for Irritable Bowel Syndrome:A Systematic Review and Meta-Analysis

Xia-Xiao Yan 1Yue-Lun Zhang 2Yu-Pei Zhang 3Ying-Yun Yang 4Dong Wu4
扫码查看

作者信息

  • 1. Department of Gastroenterology,State Key Laboratory of Complex Severe and Rare Diseases,Peking Union Medical College Hospital,Chinese Academy of Medical Sciences&Peking Union Medical College,Beijing 100730,China;Eight-Year Medical Doctor Program,Chinese Academy of Medical Sciences&Peking Union Medical College,Beijing 100730,China
  • 2. Medical Research Center,Peking Union Medical College Hospital,Chinese Academy of Medical Sciences&Peking Union Medical College,Beijing 100730,China
  • 3. Eight-Year Medical Doctor Program,Chinese Academy of Medical Sciences&Peking Union Medical College,Beijing 100730,China
  • 4. Department of Gastroenterology,State Key Laboratory of Complex Severe and Rare Diseases,Peking Union Medical College Hospital,Chinese Academy of Medical Sciences & Peking Union Medical College,Beijing 100730,China
  • 折叠

Abstract

Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,and IEEE Xplore databases until September 2023.Cross-sectional and case-control studies on diagnostic accuracy of bowel sound analysis for IBS were identified.We estimated the pooled sensitivity,specificity,positive likelihood ratio,negative likeli-hood ratio,and diagnostic odds ratio with a 95%confidence interval(CI),and plotted a summary receiver operat-ing characteristic curve and evaluated the area under the curve.Results Four studies were included.The pooled diagnostic sensitivity,specificity,positive likelihood ratio,nega-tive likelihood ratio,and diagnostic odds ratio were 0.94(95%CI,0.87‒0.97),0.89(95%CI,0.81‒0.94),8.43(95%CI,4.81‒14.78),0.07(95%CI,0.03‒0.15),and 118.86(95%CI,44.18‒319.75),respectively,with an area under the curve of 0.97(95%CI,0.95‒0.98).Conclusions Computerized bowel sound analysis is a promising tool for IBS.However,limited high-quality data make the results'validity and applicability questionable.There is a need for more diagnostic test accuracy studies and better wearable devices for monitoring and analysis of IBS.

Key words

irritable bowel syndrome/bowel sound analysis/diagnostic accuracy/systematic review/meta-analysis

引用本文复制引用

基金项目

National Natural Science Foundation of China(32170788)

National High Level Hospital Clinical Research Funding(2022-PUMCH-B-023)

Beijing Natural Science Foundation(7232123)

出版年

2024
中国医学科学杂志(英文版)
中国医学科学院,中国协和医科大学

中国医学科学杂志(英文版)

CSTPCD
影响因子:0.533
ISSN:1001-9294
段落导航相关论文