首页|临沂市罗庄区浅层地热能资源研究与评价——以地埋管地源热泵系统为例

临沂市罗庄区浅层地热能资源研究与评价——以地埋管地源热泵系统为例

扫码查看
本研究旨在评估临沂市罗庄区浅层地热能资源量和开发利用潜力.在分析临沂市罗庄区区域地质、地热地质等基础资料的基础上,结合岩土体样品测试和现场热响应试验,采用指标法和层次分析法对临沂市罗庄区进行地埋管地源热泵系统进行适宜性区划并进行了潜力计算.结果表明:罗庄区内浅层地热能开发利用适宜性中等区面积 68.97 km2,占 97.17%;适宜区内,0~120 m浅层地热能储存量 1.882×1013 kJ/℃.研究区采取地埋管地源热泵方式开采浅层地热能,冬季可供取暖面积 2.56×107 m2,夏季供可制冷面积 1.56×107 m2.
Research and evaluation of shallow geothermal energy resources in luozhuang,Linyi City——Take the ground source heat pump system with ground pipe as an example
The purpose of this study is to evaluate the shallow geothermal energy resources and its development and utiliza-tion potential in luozhuang,Linyi City.On the basis of analyzing the basic data of geology and geothermal geology in luozhuang area of Linyi City,combined with the test of rock and soil samples and the field thermal response test,the suitability zoning of ground source heat pump system in luozhuang City of Linyi City was carried out by using the index method and analytic hierar-chy process,and the potential was calculated.The results show that the moderate area of shallow geothermal energy develop-ment and utilization in luozhuang is 68.97 km2,accounting for 97.17%.In the suitable area,the shallow geothermal energy storage of 0~120 m is1.882×1013 kJ/℃.In the study area,shallow geothermal energy is exploited by ground source heat pump,with heating area of 2.56×107 m2 in winter and cooling area of 1.56×107 m2 in summer.

shallow geothermal energyground source heat pump with buried piperesource evaluationLuozhuang Dis-trict,Linyi City

石林、张永帅、周亮宇、郭雷、刘孝峰、荣玉伟

展开 >

河北地质大学地球科学学院,河北石家庄 050031

山东省地质矿产勘查开发局第七地质大队,山东临沂 276002

浅层地热能 地埋管地源热泵系统 资源评价 临沂市罗庄区

山东省地勘项目

鲁国土资函[2017]151号

2024

地下水
陕西省水工程勘察规划研究院 全国地下水信息网 陕西省水利学会

地下水

影响因子:0.219
ISSN:1004-1184
年,卷(期):2024.46(3)
  • 9