目的:用自制抗体研制可在自动生化分析仪应用的颗粒增强透射免疫浊度分析法(PETIA)定量测定人血清胱抑素C(Cys C)的试剂盒.方法:构建人Cys C的原核表达载体pET32a(+)/Cys C,纯化Cys C重组蛋白并免疫大白兔,制备Cys C抗血清;以自制的Cys C抗血清包被乳胶颗粒,研制PETIA法定量检测血清Cys C的试剂盒,并对其分析性能进行方法学评价.结果:本法回收率为97.5%~105.0%,批内及批间CV均<5%,线性范围8.11~0.25 mg/L,检测限0.2 mg/L;本法与Dako法和BN-Prospect法呈正相关(P<0.0001);胆红素对高浓度Cys C测定有干扰作用,Hb和葡萄糖对本法无干扰.结论:应用自动生化分析仪的自研法性能满意.
Evaluation of particle enhanced turbidimetric immunoassay method for human serum Cys C with selfpreparing antibody
AIM:To develop a kit of particle enhanced turbidimetric immunoassay(PETIA)method based on self-made antibody for determining human serum Cys C level with automatic biochemical analyzer.METHODS:The prokaryotic expression vector pET32a(+)/Cys C was constructed,in which Cys C expression was induced.The antiserum was prepared after rabbits were immunized with the purified recombinant protein.Then the antibody was covalently attached to the uniform microparticles,a kit of PETIA method for human serum Cys C test was established,and methodology evaluations were done.RESULTS:The recovery rate was 97.5%-105.0%,CV was less than 5%,linear range 8.11-0.25 mg/L,minimum limit 0.2 mg/L.The performance of self-established PETIA was equal to the import kits(Dako & BN-Prospect).The bilirubin had an effect on assays of high level Cys C,while Hb and glucose had no interference.CONCLUSION:The kit of PETIA based on serf-preparing antibody to test human serum Cys C levels could be applied in automatic biochemical analyzer with satisfactory performance.

cystatin Cantiserumparticle enhanced turbidimetric immunoassayevaluation test of methodology

陈婷梅、俸家富、郭变琴、文阳安、涂植光

展开 >

重庆医科大学检验系,教育部临床检验诊断学重点实验室,重庆,400016

绵阳市中心医院检验科,四川,绵阳,621000

胱抑素C 抗血清 颗粒增强透射免疫浊度分析法 方法学评价

2009

第四军医大学学报
第四军医大学

第四军医大学学报

CSTPCDCSCD北大核心
影响因子:0.599
ISSN:1000-2790
年,卷(期):2009.30(21)
  • 2