Study and Analysis of GJB 150.7A—2009 Solar Radiation Test Method
The development and framework of GJB 150.7A—2009 solar radiation test standard are introduced,and the procedures and methods in the standard to some extent are introduced. The program I steady-state test and program Ⅱ daily cycle test in the standard,as well as the difference between the infrared radiation and the full spectrum radiation of the solar radiation test lamp source in the test nature,the test purpose,the simulation environment and the application object are analyzed. The GJB 150.7A—2009,GJB 150.3A—2009,GJB 150.7—1986 standards are compared,which is helpful for relevant technical personnel in the field of product development and environmental test to better carry out tests according to GJB 150.7A—2009,improve the quality and effectiveness of the test,and implement the guiding role of standards.
GJB 150.7A—2009full-spectrum radiationinfrared radiationhigh temperature testsolar radiationthermal effectphotochemical effect