In order to benchmark the reasonable energy consumption of public institutions,both the national and Jiangsu provincial energy consumption quota standards and the indicator types specified in the reasonable energy use guidelines are analyzed.The methods of benchmarking with single indicators(energy consumption per unit area)and double indicators(energy consumption per unit area,and energy consumption per capita)are expounded,and the indicator judgment intervals and regional expressions are obtained,and the two methods are compared.A comprehensive benchmarking method for energy consumption per unit area and energy consumption per capita is proposed,and the mathematical expressions and regional expressions of indicator quotas are derived.Taking the energy consumption quota for primary and secondary schools in the"Energy Consumption Quota and Calculation Method of Public Institutions"as an example,the comprehensive benchmarking limits and regional expressions for energy consumption per unit area and energy consumption per capita are derived.The energy consumption per unit area and energy consumption indicators per capita of a primary school in Nanjing is studied,the benchmarking results of three methods are compared and analyzed,providing a reference for benchmarking energy consumption indicators of public institutions.
energy consumption per unit areaenergy consumption per capitaenergy consumption quotaenergy audit