首页|固相萃取GC-MS/MS法测定水中15种硝基苯类化合物

固相萃取GC-MS/MS法测定水中15种硝基苯类化合物

扫码查看
经C18固相萃取柱富集,利用气相色谱/三级四级杆质谱联用仪(GC-MS/MS)对水中15种硝基苯类化合物进行测定.优化条件下,15种硝基苯类化合物供试品在0.1~10.0 mg/L浓度范围内线性关系良好;以原始水样计,检出限低至0.004~0.02 μg/L;方法精密度,在两种浓度水平下,相对标准偏差(RSD)范围为1.04%~13.79%;加标回收率范围为76.4%~102.2%.用所开发方法分析了盐城市某点位水样,结果显示该样品中检出2,6-二硝基甲苯、硝基苯、间-硝基甲苯、邻-硝基氯苯和对-硝基氯苯等5种硝基苯类化合物.
Determination of 15 Nitrobenzene compounds in water by GC/MS/MS Solid Phase Extraction
The determination of 15 Nitrobenzene compounds in water was carried out by GC/MS/MS with solid phase appara-tus.Under the optimized conditions,the linear relationship was good in the concentration range of 0.1-10.0 mg/L,and the relative standard deviation(RSD)of 15 components was 4.07%-13.28%.When the Sampling volume was 1 000 mL,the detection limit of 15 nitrobenzene compounds was 0.004-0.02 μg/L.The relative standard deviation(RSD)of the two blank supplementary samples with different concentrations was1.04%-12.7%.The spiked recoveries was 76.4%-102.2%.The ni-trobenzene compounds in water at a certain point in Yancheng City were analyzed by the established method.The results showed that 5 nitrobenzene compounds were detected in the sample,including nitrobenzene,m-nitrotoluene,o-nitrochloro-benzene,p-nitrochlorobenzene and 2,6-dinitrotoluene.

Solid Phase ExtractionGC/MS/MSWateNitrobenzene Compounds

赵有政

展开 >

江苏省盐城环境监测中心,江苏 盐城 224002

固相萃取 GC/MS/MS 硝基苯化合物

2024

福建分析测试
福建省测试技术研究所

福建分析测试

影响因子:0.365
ISSN:1009-8143
年,卷(期):2024.33(3)