以某旅检大楼为例,通过对福建平潭综合试验区水文气候等自然条件进行分析,确定海水源热泵系统设计方案及技术要点,结合投资回收期分析判断经济可行性,为平潭综合试验区类似项目提供一定的设计经验参考.
Application analysis of seawater source heat pump system in Pingtan comprehensive test area-Take a travel inspection building as an example
Taking a travel inspection building as an example,by analyzing the natural conditions such as hydrology and climate in the Ping-tan Comprehensive Experimental Area of Fujian,the design scheme and technical points of the seawater source heat pump system were de-termined,and the economic feasibility was judged by combining the payback period analysis,so as to provide certain design experience ref-erence for similar projects in the Pingtan Comprehensive Experimental Zone.

seawater source heat pump systemenergy saving and emission reduction

杨淑波

展开 >

福建省建筑科学研究院有限责任公司 福建省绿色建筑技术重点实验室 福建福州 350108

海水源热泵系统 节能减排