首页|腰椎终板Modic改变相邻结构的磁共振脂肪定量比较

腰椎终板Modic改变相邻结构的磁共振脂肪定量比较

扫码查看
目的 对腰椎终板Modic改变相邻结构的磁共振(MR)脂肪定量进行比较。方法 (1)以终板Modic改变发生率最高的L5~S1椎间盘为研究对象,收集腰椎终板Modic改变患者55名,在常规腰椎MRI扫描后加用脂肪分析计算技术(FACT)序列扫描;(2)测量各终板Modic改变上椎体脂肪分数面积加权值(SFFaw)、下椎体脂肪比面积加权值(IFFaw)、邻近双侧腰大肌和多裂肌的脂肪分数面积加权值(FFaw)、髓核T2信号强度(SI)值及Pfirrmann评分;(3)比较L5~S1各终板Modic改变的SFFaw、IFFaw、腰大肌和多裂肌的FFaw及Pfirrmann评分的差异;(4)分析L5~S1椎间盘Modicl型、2型的SFFaw、IFFaw、腰大肌和多裂肌的FFaw与髓核T2信号SI值的相关性;(5)分析L5~S1椎间盘所有终板Modic改变的SFFaw、IFFaw、腰大肌FFaw、多裂肌FFaw与Pfirrmann评分值的相关性。结果 (1)L5~S1椎间盘 Modic1、Modic 2、Modic 3 的 SFFaw、IFFaw、多裂肌 FFaw、腰大肌 FFaw、髓核 T2 信号 SI 值、Pfirrmann 评分值的差异有统计学意义(P<0。05)。(2)L5~S1椎间盘Modic1、Modic 2的SFFaw、IFFaw、多裂肌FFaw、腰大肌FFaw值与髓核T2信号SI值呈Spearman负相关,P<0。05,有统计学意义;(3)L5~S1椎间盘所有终板Modic改变的SFFaw、IFFaw、腰大肌FFaw、多裂肌FFaw与椎间盘的Pfirrmann评分呈正相关,P<0。05,有统计学意义。结论 L5~S1椎间盘各终板Modic改变相邻结构的脂肪含量比较有差异,并与椎间盘的退变存在一定的相关性。
MR fat quantification comparison on adjacent structures of lumbar endplate Modic change
Objective To compare fat quantification in adjacent structures of lumbar endplate Modic change.Methods The L5-S1 intervertebral disc with the highest incidence of Modic was taken as the research object,55 patients with endplate Modic change were collected,and the FACT sequence scan was added after the routine lumbar MRI scan;The area-weighted value of fat fraction in the upper vertebral body(SFFaw),the area-weighted value of fat ratio in the lower vertebral body(IF-Faw),the area-weighted value of fat fraction in the adjacent bilateral psoas major muscle and multifidus(FFaw),the T2 signal SI value of the nucleus pulposus and the Pfirrmann score were measured;The differences in SFFaw,IFFaw,FFaw of psoas ma-jor muscle and multifidus,and Pfirrmann score of each Modic of L5-S1 intervertebral disc were compared;The correlations be-tween SFFaw,IFFaw,FFaw of psoas major muscle and multifidus of Modic1 and 2 of L5-S1 intervertebral disc and the T2 signal SI value of the nucleus pulposus were analyzed;The correlations between SFFaw,IFFaw,FFaw of psoas major muscle and mul-tifidus of all endplate Modic change of L5-S1 intervertebral disc and the Pfirrmann score were analyzed.Results There were sta-tistically significant differences in SFFaw,IFFaw,FFaw of multifidus,FFaw of psoas major,T2 signal SI value of nucleus pul-posus,and Pfirrmann score among Modic 1,Modic 2,and Modic 3 of L5-S1 intervertebral disc(P<0.05).The values of SF-Faw,IFFaw,FFaw of multifidus,and FFaw of psoas major in Modic 1 and Modic 2 of L5-S1 intervertebral disc were negatively correlated with the T2 signal SI value of the nucleus pulposus(P<0.05),which was statistically significant.The SFFaw,IF-Faw,FFaw of psoas major,and FFaw of multifidus of all endplate Modic change of L5-S1 intervertebral disc were positively cor-related with the Pfirrmann score of the intervertebral disc(P<O.05).Conclusion There are differences in the fat content of ad-jacent structures of each endplate Modic change of L5-S1 intervertebral disc,and there is certain correlation with the degeneration of the intervertebral disc.

intervertebral discendplate Modic changefat quantification

蔡铭圳、蔡建忠、田青松、李伟瞳、邱志平

展开 >

福建省石狮市医院影像科,石狮 362700

椎间盘 终板Modic改变 脂肪定量

2024

福建医药杂志
中华医学会福建分会

福建医药杂志

影响因子:0.525
ISSN:1002-2600
年,卷(期):2024.46(6)