There are few researches on the influence of viscous dampers attached to isolation layer on dynamic response of high-rise foundation isolation structure.A 15-floor ward building in a hospital was selected as the object,and two kinds of structures before and after the isolation layer with viscous damper were selected to analyze the elastic-plastic time history of three-directional ground motion.The results show that the interlayer shear force increases by 21.3%when the viscous damper is added to the isolation layer.The first floor story drift decreases about 15%,and the middle and upper floors story drift increases about 4%.The displacement of the isolation layer can be reduced by 33.6%,which can effectively reduce the tensile stress of the isolator units,but has no obvious effect on the compressive stress.
关键词
高层建筑/隔震结构/黏滞阻尼器/弹塑性时程/动力响应
Key words
high-rise building/isolation structure/viscous damper/elastoplastic time history/dynamic response