Effect of Molding Method on RCM Method of Chloride Ion Diffusion Coefficient
In order to reduce the influence of standard test mode on the chloride diffusion coefficient of cement concrete antichloride penetration test method(RCM method),to ensure more effectively and truly reflect the engineering entity durability,and ensure the performance of concrete quality and durability during the structural service period,this paper recommends the use of cement concrete cube test mold(150 mm×150 mm×150 mm)to reduce the influence of molding method on RCM chloride diffusion coefficient.
highway and waterway engineeringtest detectionmolding methodRCM methodchloride ion diffusion coefficient