供水管网的夜间最小流量(MNF)在漏损程度评估中起到重要作用,其数值大小对评估准确度有很大影响.以广东省某市供水管网为例开展夜间最小流量监测实验,研究取值时间固定与否、匹配时间区段、取值时间间隔对夜间最小流量数值的影响,并据此探讨了更加合理的夜间最小流量确定方法.研究结果显示,夜间最小流量较夜间最小流量时刻流量(MNFTF)能取到更小数值,约偏低 5.18%;匹配时间区段不局限在 02:00-04:00;取值时间间隔为 10、15、20、30、60、90、120 min时,较5 min时夜间最小流量分别平均高 15.70%、22.95%、27.81%、33.00%、42.08%、49.39%、60.34%.这表明为了得到更小的夜间最小流量,其取值方法存在较大的优化空间,在我国夜间最小流量建议匹配时间区段放宽到 00:00-06:00,取值时间间隔要尽可能短,优先考虑不固定取值时间的方法.
Optimization of the Method for Determining the Minimum Night Flow of Water Supply Network
The minimum night flow(MNF)in the water supply network plays an important role in evaluating the degree of leakage,and its numerical value has a significant impact on the accuracy of the evaluation.This article conducted a minimum night flow monitoring experiment on the water supply network in a certain city,Guangdong Province,to study the influence of fixed value time,matching time period,and value interval on the minimum night flow value.Based on this,we explored a more reasonable method for determining the minimum night flow.The research results showed that the minimum night flow was smaller than the minimum nighttime flow time flow(MNFTF),which was about 5.18%lower;The matching time range was not limited to 02:00 am to 04:00 am;When the value intervals were 10,15,20,30,60,90,120 min,the MNF values were 15.7%,22.95%,27.81%,33.00%,42.08%,49.39%,and 60.34%higher than those of 5 min,respectively.This indicated that there was significant room for optimization in the method of obtaining a smaller minimum night flow.In China,it was recommended to relax the matching time range to 00:00 am to 06:00 am for the minimum night flow,shorten the value interval as much as possible,and prioritize methods with variable value times.

water supply networkpipeline leakagedistrict metering area(DMA)minimum night flow(MNF)

郑成志、钟丹、周锦博、王晶惠、孙国胜

展开 >

广东粤海水务股份有限公司,广东 深圳 518021

哈尔滨工业大学水资源国家工程研究中心有限公司,黑龙江 哈尔滨 150090

城市水资源开发利用(北方)国家工程研究中心,黑龙江 哈尔滨 150090

哈尔滨工业大学环境学院,黑龙江 哈尔滨 150090

展开 >

供水管网 管网漏损 独立计量分区 夜间最小流量

2024

供水技术
天津市自来水集团有限公司

供水技术

影响因子:0.293
ISSN:1673-9353
年,卷(期):2024.18(6)