To address the issue of red light filament breakage transfer for home signals at stations employing automatic blocking,particularly in cases where the distance between two stations is too short to install section passing signals or section block partition signal signs within the interval,this paper investigates four application scenarios,including stations with permanently illuminated signals under CTCS-0 Train Control System,stations with permanently illuminated signals under CTCS-2 Train Control System,stations with normally extinguished signals under CTCS-2 Train Control System,and stations with normally extinguished signals under CTCS-3 Train Control System.Based on the operational situations in each scenario,solutions for red light filament breakage transfer for home signals are proposed,which can serve as a reference for similar engineering practices.
short intervalred light filament breakage transferscenario analysissolution