Laboratory research on simultaneous dephosphorization and desulfurization of medium-phosphorus hot metal
In view of medium-phosphorus hot metal with the phosphorus content between 0.33 % and 0.44 %,a optimization test on simultaneous dephosphorization and desulfurization slag system was carried out by injection treatment at 1 350 ℃.The results showed that CaO excess coefficient,oxidizer excess coefficient,and ω(CaF2)/ω(CaO) ratio had little effect on dephosphorization,but influenced desulphurization quite appreciably.With the combined consideration to dephosphorization rate,desulphurization rate,and slag quantity,the optimum agent composition was CaO excess coefficient of 45 %,oxidizer excess coefficient of 15 %,and ω (CaF2)/ω (CaO) of 0.5.To substitute B2O3 for CaF2,the ω(B2O3)/ω(CaO) ratio should be maintained above 0.20.
medium-phosphorus hot metaldephosphorizationdesulfurization