Research on the radiation field distribution in industrial irradiation accelerators maze
The main sources of the radiation field in the accelerator maze through field monitoring and theoretical analysis were analyzed,and the radiation field distribution in the maze based on the actual measurement was simulated and quantified.The longitudinal radiation field in the labyrinth was evenly distributed.In the first segment of the maze,the radiation field in the maze mainly came from the scattering lines inside the maze,and the influence of transmitted rays was minimal.For the second segment of the maze,the radiation field inside the maze mainly came from the scattered lines and transmitted rays,and their contributions were equivalent.The research results provided valuable reference and data for the radiation field distribution in the maze of this type of accelerator and had important practical significance for improving the radiation protection standard system of this type of accelerator.
industrial irradiation acceleratormazemonte Carlo programradiation measurementradiation field distribution