环境与健康杂志2024,Vol.41Issue(3) :251-255.DOI:10.16241/j.cnki.1001-5914.2024.03.015

尿液中16种稀土元素的电感耦合等离子体质谱同时测定法

Simultaneous determination of 16 rare earth elements in urine by inductively coupled plasma mass spectrometry

田婧 宣栋樑 彭谦
环境与健康杂志2024,Vol.41Issue(3) :251-255.DOI:10.16241/j.cnki.1001-5914.2024.03.015

尿液中16种稀土元素的电感耦合等离子体质谱同时测定法

Simultaneous determination of 16 rare earth elements in urine by inductively coupled plasma mass spectrometry

田婧 1宣栋樑 1彭谦1
扫码查看

作者信息

  • 1. 上海市嘉定区疾病预防控制中心理化检验科,上海 201800
  • 折叠

摘要

目的 建立尿液中16种稀土元素(包括镧、铈、镨、钕、铕、钆、镝、钐、铽、钬、铒、铥、镱、镥、钪和钇)的电感耦合等离子体质谱同时测定法.方法 尿液经1%硝酸直接稀释10倍后过滤,选择ICP-MS标准模式和标准加入法进样测定稀土元素的浓度.结果 钪的线性范围为0.1~10 μg/L,其余15种稀土元素的线性范围为0.05~10 μg/L,所得回归方程的线性关系良好,r>0.999.方法的检出限为0.017~0.215 μg/L,定量下限为0.052~0.718 μg/L;加标回收率为92.1%~107.2%,RSD为0.2%~7.4%.结论 该方法准确、快速、稳定且灵敏度高,适用于尿液中16种稀土元素的同时分析.

Abstract

Objective To establish a test method for simultaneous determination of 16 rare earth elements in urine by inductively coupled plasma mass spectrometry,including lanthanum,cerium,praseodymium,neodymium,europium,gadolinium,dysprosium,samarium,terbium,holmium,erbium,thulium,ytterbium,lutetium,scandium and yttrium.Methods The urine was diluted 10 times with 1%nitric acid and then filtered,ICP-MS standard mode and standard addition method were used to determine the concentration of rare earth elements.Results The linear range of scandium was 0.1-10 μg/L,and the linear range of the remaining 15 rare earth elements was 0.05-10 μg/L,the linear relationship of regression equation was good,r>0.999.The limit of detection was 0.017-0.215 μg/L,the limit of quantitations were 0.052-0.718 μg/L.The recoveries were 92.1%-107.2%.The RSDs were 0.2%-7.4%.Conclusion This method is accurate,rapid,stable and highly sensitive and is applicable to the simultaneous analysis of 16 rare earth elements in urine.

关键词

尿/稀土元素/电感耦合等离子体质谱

Key words

Urine/Rare earth elements/Inductively coupled plasma mass spectrometry

引用本文复制引用

基金项目

2022年嘉定区卫生健康委科研立项项目(2022-KY-25)

出版年

2024