目的 建立生活饮用水和废水中19种农药的高效液相色谱-串联质谱测定方法.方法 水样经PTFE膜过滤后上机测定,采用C18柱(2.1 mm×50 mm,1.7μm)进行分离,以甲醇-0.1%甲酸水为流动相,梯度洗脱,以MRM正离子或负离子模式进行测定.结果 在0.004~500 μg/L的范围内,所得19种农药的回归方程均呈良好的线性关系,r≥0.998 9.该方法的检出限为0.001 0~2.500 0 μg/L,定量下限为0.004~10.000 μg/L.该方法在生活饮用水及其水源水中的回收率为86.0%~106.0%,RSD为0.9%~5.7%;在污水厂进水及出水中的回收率为85.2%~97.6%,RSD为3.6%~8.4%.结论 该方法简单快速,灵敏度较高,准确度及精密度均较好,适用于生活饮用水和废水中19种农药的测定.
Determination of nineteen pesticides in drinking water and waste water by ultra-performance liquid chromatography-mass spectrometry
Objective To establish a method for the determination of nineteen pesticides in drinking water and waste water by ultra-performance liquid chromatography-mass spectrometry.Methods The water samples were directly determined on ultra-performance liquid chromatography-mass spectrometry after being filtered by PTFE filter membrane.The pesticides were separated by C18 column(2.1 mm×50 mm×1.7 μm)using a programmed gradient elution with a mobile phase of methanol and 0.1%formic acid aqueous solution.The pesticides were detected by MRM negative or positive ion mode.Results In the range of 0.004-500 μg/L,the regression equations of 19 pesticides showed a good linear relationship,r ≥0.998 9.The limit of detection was 0.001 0-2.500 0 μg/L,and the lower limit was 0.004-10.000 μg/L.The recoveries of water samples from drinking water and source water at three concentrations were in the ranges of 86.0%-106.0%and the relative standard deviations were in the ranges of 0.9%-5.7%.The recoveries of waste water at three concentrations were in the ranges of 85.2%-97.6%and the relative standard deviations were in the ranges of 3.6%-8.4%.Conclusion The sensitivity,accuracy and precision of the method all meet the requirements of the determination of pesticides.The rapid,efficient and high-throughput method is applicable to the determination of pesticides in water and waste water.

Ultra-performance liquid chromatography-mass spectrometryPesticidesDrinking waterWaste water

冯桂学、辛晓东、刘莉、陈燕、王明泉、贾瑞宝

展开 >

山东省城市供排水水质监测中心,济南 250021

超高效液相色谱-串联质谱 农药 生活饮用水 废水

2024

环境与健康杂志
中华预防医学会,天津市疾病预防控制中心

环境与健康杂志

CSTPCD
影响因子:0.658
ISSN:1001-5914
年,卷(期):2024.41(11)