介入放射学杂志2024,Vol.33Issue(6) :623-626.DOI:10.3969/j.issn.1008-794X.2024.06.007

XperCT联合穿刺引导下Glubran-2胶肺小结节定位在胸腔镜肺结节切除术的临床应用

Clinical application of XperCT combined with needle-guided Glubran-2 glue for small pulmonary nodule localization in thoracoscopic pulmonary nodule resection

张洁 曹景勤 刘显 来龙祥 王前 张迎春 范冬利 张德芬
介入放射学杂志2024,Vol.33Issue(6) :623-626.DOI:10.3969/j.issn.1008-794X.2024.06.007

XperCT联合穿刺引导下Glubran-2胶肺小结节定位在胸腔镜肺结节切除术的临床应用

Clinical application of XperCT combined with needle-guided Glubran-2 glue for small pulmonary nodule localization in thoracoscopic pulmonary nodule resection

张洁 1曹景勤 1刘显 1来龙祥 1王前 1张迎春 1范冬利 1张德芬1
扫码查看

作者信息

  • 1. 272000 山东济宁 济宁市第一人民医院介入放射科
  • 折叠

摘要

目的 探讨XperCT联合穿刺引导下Glubran-2胶肺小结节定位在胸腔镜肺结节切除术的应用价值.方法 回顾性分析2018年6月至2023年2月于济宁市第一人民医院单发肺小结节行胸腔镜切除术前在XperCT联合穿刺导航引导下采用Glubran-2胶定位67例患者的临床资料.统计肺结节大小、距脏层胸膜垂直的最大距离、定位技术成功率、穿刺次数、并发症、操作时间、术后病理结果.结果 67例患者肺小结节平均最大直径8.7 mm,距脏层胸膜19.4 mm,均顺利完成术前定位,平均穿刺次数1.1次,未出现严重并发症,平均操作时间12.7 min,均获得明确的病理结果.结论 XperCT联合穿刺导航引导下Glubran-2胶肺小结节定位准确、并发症少,是一种高效快速的定位方式,具有临床应用价值.

Abstract

Objective To discuss the application value of XperCT combined with needle-guided Glubran-2 glue for small pulmonary nodule localization in thoracoscopic pulmonary nodule resection.Methods The clinical data of 67 patients,who received XperCT combined with needle-guided Glubran-2 glue for small pulmonary nodule localization before thoracoscopic resection of a single small pulmonary nodule at the Jining Municipal First People's Hospital of China between June 2018 and February 2023,were retrospectively analyzed.The size of the pulmonary nodule,the maximum vertical distance from the visceral pleura to the lesion,the technical success rate of localization,the number of puncturing times,the complications,the time spent for operation,and the postoperative pathological diagnosis were recorded.Results The average size of the small pulmonary nodules in the 67 patients was 8.7 mm,and the average vertical distance from the visceral pleura to the lesion was 19.4 mm.Successful preoperative localization of nodule was accomplished in all patients.The average number of puncturing times was 1.1,and no serious complications occurred.The average time spent for operation was 12.7 min.Definite pathological results were obtained in all 67 patients.Conclusion XperCT combined with needle-guided Glubran-2 glue for small pulmonary nodule localization carries advantage of accurate localization with fewer complications.Therefore,this technique is a highly-efficient and quickly-accomplished positioning method,and it is highly valuable in clinical practice.(J Intervent Radiol,2024,33:623-626)

关键词

穿刺导航/Glubran-2胶/肺小结节/定位

Key words

needle navigation/Glubran-2 glue/small pulmonary nodule/localization

引用本文复制引用

出版年

2024
介入放射学杂志
上海市医学会

介入放射学杂志

CSTPCD北大核心
影响因子:1.866
ISSN:1008-794X
参考文献量9
段落导航相关论文