首页|基于局部放电测试技术的避雷器状态诊断方法研究

基于局部放电测试技术的避雷器状态诊断方法研究

扫码查看
避雷器经过长时间使用或受到外界环境的影响,可能会出现老化、损坏或失效的情况,影响避雷器状态诊断准确性,为保证避雷器状态的带电诊断性能,提出基于局部放电测试技术的避雷器状态诊断方法;模拟内部气隙、尖刺、沿面等局部放电现象的产生过程,确定不同局部放电状态下避雷器的运行特征,以此作为避雷器状态诊断标准;优化设计避雷器局部放电信号采集设备,利用该设备采集避雷器的实时状态信号,从统计和时频域两个方面,提取避雷器运行状态特征;利用局部放电测试技术,计算避雷器放电参数,通过特征匹配度和放电参数的比对,得出避雷器状态的诊断结果;实验结果表明,在200 kV和500 kV避雷器中,所提方法平均局部放电量诊断误差分别为0。5 pc和1。0pc,局部放电相位幅值诊断误差0。01 V和0。01 V,状态诊断准确率平均值为99。5%和99。6%。
Research on Condition Diagnosis Method of Arrester Based on Partial Discharge Testing Technology
Due to longtime use or external environmental influences,there are the phenomena of aging,damage,or failure in lightning arresters,which affects the accuracy of lightning arrester status diagnosis.To ensure the live diagnosis performance of light-ning arrester status,a lightning arrester status diagnosis method based on partial discharge testing technology is proposed.Simulate the generation process of internal air gap,spike,surface and other partial discharge phenomena,determine the operation characteris-tics of the arrester under different partial discharge conditions,which is taken as the diagnosis standard of the arrester status.Opti-mize the design of partial discharge signal acquisition equipment for lightning arresters,use this equipment to collect real-time status signals of lightning arresters,and extract operational status characteristics of lightning arresters from both statistical and time-fre-quency domain aspects.The partial discharge testing technology is used to calculate the discharge parameters of the lightning arrester,and obtain the diagnostic results of the lightning arrester status through the comparison of feature matching and discharge parameters.The experimental results show that in 200 kV and 500 kV lightning arresters,the average diagnostic errors of the proposed method for partial discharge quantity are 0.5pc and 1.0pc,respectively,the diagnostic errors for partial discharge phase amplitude are 0.01V and 0.01 V,and the average accuracy of state diagnosis is 99.5%and 99.6%.

partial discharge testing technologylightning arresterstatus diagnosisfeature matching degreedischarge parame-ters

江熠、金坤鹏、钱锡颖、任一舟

展开 >

宁波送变电建设有限公司,浙江宁波 315032

局部放电测试技术 避雷器 状态诊断 特征匹配度 放电参数

2024

计算机测量与控制
中国计算机自动测量与控制技术协会

计算机测量与控制

CSTPCD
影响因子:0.546
ISSN:1671-4598
年,卷(期):2024.32(7)