首页|不同温度条件下5种流体树脂微渗漏程度的对比研究

不同温度条件下5种流体树脂微渗漏程度的对比研究

扫码查看
目的 研究温度对Beautifil Flow Plus F00、FiltekTM Z350 XT、SDR、Tetric®N-Flow、Constic这5 种流体树脂微渗漏的影响,为临床选择较理想的流体树脂提供参考.方法 选取因正畸拔除的成人离体前磨牙 60 颗,随机分为 10 组(n=12),根据是否经过冷热循环老化实验,分为F00A组、Z350A组、SDRA组、TetricA组、ConsticA组,F00B组、Z350B组、SDRB组、TetricB组、ConsticB组,共 10 组.每颗离体牙咬合面预备成宽2 mm、长4 mm、深2mm的Ⅰ类洞,分别用所属组别流体树脂充填,A组试件亚甲基蓝染色实验,B组试件先进行 5 000 次冷热循环老化实验后再进行亚甲基蓝染色实验,之后将所有试件牙冠部沿颊舌(腭)方向平行于牙体长轴纵向剖开,体视显微镜下观察各组微渗漏情况,记录数据并分析.结果 ①F00A组、Z350A组、SDRA组、TetricA组、ConsticA组 5 组微渗漏的差异并没有统计学意义(P>0.05).②SDRB组、TetricB组的微渗漏程度大于F00B组、Z350B组,差异具有统计学意义(P<0.05).③温度对 Beautifil Flow Plus F00、FiltekTM Z350 XT、SDR、Tetric® N-Flow、Constic这 5 种流体树脂之间的微渗漏程度影响有显著差异(P<0.05).结论 ①未经过冷热循环老化实验时,Beautifil Flow Plus F00、FiltekTM Z350 XT、SDR、Tetric®N-Flow、Constic这5 种流体树脂的即刻微渗漏程度无明显差异.②经过冷热循环老化实验后,SDR流体树脂、Tetric® N-Flow流体树脂微渗漏程度较高,边缘密合性不佳;Beautifil Flow Plus F00 流体树脂、FiltekTM Z350 XT流体树脂微渗漏程度较低,边缘密合性较优.③冷热循环老化实验加重了Beautifil Flow Plus F00、FiltekTM Z350 XT、SDR、Tetric® N-Flow、Constic这 5 种流体树脂的微渗漏程度.
Comparative study on microleakage degree of five kinds of fluid resins under different temperature conditions
Objective To study the effect of temperature on microleakage of Beautifil Flow Plus F00,FiltekTM Z350 XT,SDR,Tet-ric®N-Flow and Constic,and to provide reference for clinical selection of ideal fluid resins.Methods A total of 60 adult detached premolars removed for orthodontic extraction were divided into 10 groups(n=12),which were divided into F00A group,Z350A group,SDRA group,TetricA group and ConsticA group according to whether they had undergone cold and hot cycle aging test,and F00B group,Z350B group,SDRB group,TetricB group,ConsticB group,a total of 10 groups.The occlusal surface of each isolated tooth was prepared into a type Ⅰhole with the width of 2 mm,length of 4 mm and depth of 2 mm,which was filled with the corresponding fluid resin respectively.Methylene blue staining experiment was performed on specimens in group A,and methylene blue staining experiment was performed on specimens in group B after 5 000 times of cold and hot cycling aging experiment.The crowns of all specimens were dissected longitudinally along the long axis of the tooth body from the direction of buccal tongue(palate).The degree of microleakage in each group was observed under stereomicroscope,and the data were recorded and analyzed statistically.Results ①There was no sig-nificant difference in the degree of microleakage between the F00A group,the Z350A group,the SDRA group,the TetricA group and the ConsticA group(P>0.05).②The degree of microleakage in the SDRB group and TetricB group was significantly higher than that in the F00B group and Z350B group(P<0.05).③Temperature had a significant effect on the microleakage degree of Beautifil Flow Plus F00,FiltekTM Z350 XT,SDR,Tetric® N-Flow and Constic(P<0.05).Conclusion ①There was no significant difference in the de-gree of immediate microleakage of Beautifil Flow Plus F00,FiltekTM Z350 XT,SDR,Tetric®N-Flow,and Constic without cold and hot cycle aging experiments.②After the cold and hot cycle aging experiments,the microleakage degree of SDR fluid resin and Tetric® N-Flow fluid resin was high,and the edge tightness was poor.Beautifil Flow Plus F00 fluid resin and FiltekTM Z350 XT fluid resin had a low degree of microleakage and better edge tightness.③The micro-leakage degree of Beautifil Flow Plus F00,FiltekTM Z350 XT,SDR,Tetric® N-Flow and Constic was aggravated by the cold and hot cycle aging ex-periments.

fluid resinmicroleakagetemperaturehot and cold cycle

郭欣欣、荆雪、马思雨、赵莎、李涛

展开 >

河北医科大学口腔医院·口腔预防科,河北省口腔医学重点实验室,河北省口腔疾病临床医学研究中心,河北石家庄(050017)

流体树脂 微渗漏 温度 冷热循环

河北省省级科技计划

21377717D

2024

口腔医学
南京医科大学口腔医学院

口腔医学

CSTPCD
影响因子:0.641
ISSN:1003-9872
年,卷(期):2024.44(10)