1例抗-G联合抗-D抗体导致交叉配血不合的病例

A case of cross-matching incompatibility caused by anti-G combined with anti-D antibody

姜叶灵 车燕佳 汤兰桂
临床血液学杂志2024,Vol.37Issue(8) :594-596.DOI:10.13201/j.issn.1004-2806.2024.08.015

1例抗-G联合抗-D抗体导致交叉配血不合的病例

A case of cross-matching incompatibility caused by anti-G combined with anti-D antibody

姜叶灵 1车燕佳 1汤兰桂2
扫码查看

作者信息

  • 1. 常德市第一人民医院输血科(湖南常德,415000)
  • 2. 常德市第一人民医院检验科
  • 折叠

摘要

目的:通过对RhD阴性患者血清中不规则抗体的鉴定,为患者临床输血安全提供保障.方法:运用Rh血型抗原分型,细胞筛选及吸收试验对患者的血液标本进行抗体鉴定.结果:通过试验鉴定,患者血清中检出抗-G及抗-D抗体.结论:RhD阴性患者血清中的抗-G抗体导致其与RhD阴性供者配血不合.

Abstract

Objective:To identify the irregular antibodies in the serum of RhD negative patients so as to ensure the safety of clinical blood transfusion.Methods:Rh blood group antigen typing,cell screening and absorption test were used to identify antibodies in the patients'blood samples.Results:Anti-G and anti-D antibodies were detected in the serum of the patients.Conclusion:The anti-G antibody in the serum of the RhD-negative patient caused its incompatibility with the RhD-negative donor.

关键词

抗-G抗体/Rh血型抗原分型/不规则抗体

Key words

anti-G antibodys/Rh blood group antigen typing/irregular antibodys