首页|光伏光热联合双源热泵系统运行模式研究(2):供暖季系统仿真研究

光伏光热联合双源热泵系统运行模式研究(2):供暖季系统仿真研究

扫码查看
使用TRNSYS软件建立了光伏光热-双源热泵(PV/T-DSHP)系统的仿真模型.选取夏热冬冷地区某一近零能耗居住建筑作为研究对象,模拟研究了供暖季PV/T-DSHP系统在COPs切换模式下的运行特性和能耗.结果表明:平均光电效率为15.08%,平均光热效率为33.05%;水源热泵运行模式下供暖季平均COP为4.55,空气源热泵运行模式下供暖季平均COP为3.19,PV/T-DSHP系统的平均COPs为2.98;供暖季系统自满足率为61%.
Research on operating mode of photovoltaic/thermal combined dual-source heat pump systems(2):System simulation study in heating season
This paper uses TRNSYS software to establish a simulation model of a photovoltaic/thermal combined dual-source heat pump(PV/T-DSHP)system.A nearly zero energy residential building in the hot summer and cold winter zone is selected as the research object,and the operating characteristics and energy consumption of the PV/T-DSHP system under COPs switching mode during the heating season are simulated.The results show that the average photoelectric efficiency is 15.08%,and the average photothermal efficiency is 33.05%.The average COP of the heat pump unit is 4.55 in the water-source heat pump operating mode,and 3.19 in the air-source heat pump operating mode during the heating season.The average COPs of the PV/T-DSHP system is 2.98.The system self-satisfaction rate during the heating season is 61%.

photovoltaic/thermaldual-source heat pumpwater-source heat pumpair-source heat pumpoperating modenearly zero energy buildingcoefficient of performance(COP)

曲明璐、白宇森、闫楠楠、张斌

展开 >

上海理工大学,上海

光伏光热 双源热泵 水源热泵 空气源热泵 运行模式 近零能耗建筑 性能系数(COP)

上海市白玉兰人才计划浦江项目

23PJ1409400

2024

暖通空调
亚太建设科技信息研究院 中国建筑设计研究院 中国建筑学会暖通空调分会

暖通空调

CSTPCD
影响因子:0.711
ISSN:1002-8501
年,卷(期):2024.54(9)