首页|600MW机组锅炉后屏过热器爆管失效分析

600MW机组锅炉后屏过热器爆管失效分析

Failure Analysis on Tube-burst of Rear Plate Superheater of 600 MW Power Units Boiler

扫码查看
某火力发电厂 600 MW机组锅炉后屏过热器发生爆管失效事故,对锅炉后屏过热器爆管管样、后屏过热器对比管样、后屏过热器备品管样等送检管样进行了爆口宏观形貌、室温拉伸、显微组织、氧化物XRD等项目的试验,结合后屏过热器超温记录及运行参数进行分析,结果认为,此次爆管原因主要为管子使用时严重超温所致.
The tube-burst of rear plate superheater of 600 MW power units boiler of a thermal power plant occurred.The explosion tube shape,room temperature tensile test,microstructure,oxide XRD for tube sample of boiler rear plate superheater,contrast tube sample and rear plate superheater preparation tube sample were carried out and analyzed.The overtemperature record and operating parameters of rear plate superheater were analyzed.The results show that,the main reason for the tube burst is the serious overheating of the tube during the service.

rear plate superheaterblasting tubeserious over heating

李秀广

展开 >

中国大唐集团科学技术研究院有限公司 西北分公司,陕西 西安 710065

后屏过热器 爆管 严重超温

2024

热加工工艺
中国船舶重工集团公司热加工工艺研究所 中国造船工程学会船舶材料学术委员会

热加工工艺

CSTPCD北大核心
影响因子:0.55
ISSN:1001-3814
年,卷(期):2024.53(10)