首页|浅谈电力变压器事故排油方案改进

浅谈电力变压器事故排油方案改进

扫码查看
油浸式电力变压器的事故放油阀一般设置在油箱下部,针对火灾时无法近距离操作事故放油阀的问题,提出了事故排油改进方案,分析了各方案的优缺点和改进中需注意的问题,并概述了变压器的防火措施,为后续工程变压器事故排油设计和改造提供参考.
Discussion on the Improvement of Emergency Oil Discharge Scheme for Power Transformer
The emergency oil drain valve of oil-immersed power transformer is generally set at the lower part of the oil tank.In order to solve the problem that the emergency oil drain valve cannot be operated at a close dis-tance in case of fire,this paper gives the improvement scheme of emergency oil drain,analyzes the advantages and disadvantages of each scheme and the problems to be paid attention to in the improvement,and summarizes the fire prevention measures of oil-immersed power transformer,which provides reference for subsequent pro-jects.

Oil-immersed power transformerEmergency oil drain valveEmergency oil dischargeTransformer fire prevention

张梅

展开 >

四川水发勘测设计研究有限公司,四川 成都 610072

油浸式电力变压器 事故放油阀 事故排油 变压器防火

2024

四川水力发电
四川省水力发电工程学会

四川水力发电

影响因子:0.211
ISSN:1001-2184
年,卷(期):2024.43(6)