首页|150万t/a常减压装置标定数据分析

150万t/a常减压装置标定数据分析

扫码查看
基于某石化厂 150 万t/a常减压装置的生产现状,连续进行了为期3d的标定,主要考核装置的实际生产能力,各项参数是否达到设计规定的指标,考核加热炉运行能力、常减压塔的分离能力和产品质量情况以及装置的能量消耗、能耗分布情况等。通过标定分析摸清装置运行情况和不利因素,为进一步优化操作参数提供基础数据,为装置处理量的提高、技术改造、节能降耗等措施提供技术依据。
Analysis of Calibration Data for 1.5 Million t/a Atmospheric and Vacuum Distillation Unit
Based on the production status of a 1.5 million t/a atmospheric and vacuum unit in a petrochemical plant,a three-day calibration was carried out to evaluate the actual production capacity of the device,whether the parameters reached the specified design indicators,the operation capacity of the heating furnace,the separation capacity of the atmospheric and vacuum tower and the product quality,as well as the energy consumption and energy consumption distribution of the device.Through calibration analysis,we can find out the operation condition and adverse factors of the device,and provide basic data for further optimization of operation parameters,and provide technical basis for improving the processing capacity of the device,technical transformation,energy saving and consumption reduction measures.

atmospheric and vacuum unitcalibrationmaterial balanceenergy consumption