Causes and Solutions to Abnormal Fluctuations in the Liquid Level of the High-Pressure External Pump at the LNG Receiving Station
In response to the problem of abnormal fluctuations in the liquid level of the high-pressure pump at the LNG receiving station during pump startup,the reasons are analyzed based on the actual operation and phenomena of the high-pressure pump at the LNG receiving station.The analysis shows that the process conditions of the medium at the inlet of the high-pressure pump,the design and operation mode of the differential pressure Level gauge may cause the liquid level of the high-pressure pump barrel to fluctuate significantly.In response to the abnormal phenomena in the operation of high-pressure pumps,corresponding solutions have been proposed,effectively solving the problem of abnormal fluctuations in the liquid level of high-pressure pump barrels,and providing new solutions for the daily operation of high-pressure pumps in LNG receiving stations.