Determination of Vitamin B1 Content in Nourishing Pills
A method for determining vitamin B,in nourishing pills was established by high-performance liquid chromatography.C18 column(250 mm×4.6 mm,5 μm)was used with 0.05 mol/L sodium acetate solution-methanol(Vsodium acetate solution∶Vmethanol=65:35)as the mobile phase at the flow rate of 1.0 mL/min,column temperature was room temperature.The results showed that vitamin B,had a good linear relationship in the concentration range of 0~1.0 μg/mL(r=0.999 7).In precision validation,the RSD of peak area was 1.31%,and the RSD of retention time was 0.178%,the RSD in the accuracy experiment verification was 1.17%,the RSD in the repeated experimental verification was 0.779%.In the development process of different drying times,the deviation of stability content determination was 1.05%.The study provided reference and inspiration for the determination of vitamin B1 content and the development process of specialty foods.
high performance liquid chromatographyvitamin B1content determinationnourishing pills