食品与药品2024,Vol.26Issue(1) :30-33.DOI:10.3969/j.issn.1672-979X.2024.01.006

离子色谱法测定滴眼剂中抑菌剂苯扎氯铵和苯扎溴铵

Determination of Benzalkonium Chloride and Benzalkonium Bromide in Eye Drops by Ion Chromatography

夏方亮 顾晶晶 曹洪杰 王建强 雷永艳 崔玉婧
食品与药品2024,Vol.26Issue(1) :30-33.DOI:10.3969/j.issn.1672-979X.2024.01.006

离子色谱法测定滴眼剂中抑菌剂苯扎氯铵和苯扎溴铵

Determination of Benzalkonium Chloride and Benzalkonium Bromide in Eye Drops by Ion Chromatography

夏方亮 1顾晶晶 1曹洪杰 1王建强 1雷永艳 1崔玉婧1
扫码查看

作者信息

  • 1. 滨州市检验检测中心,山东滨州 256600;滨州市化学药物研发与质量控制重点实验室(筹),山东滨州 256600
  • 折叠

摘要

目的 采用离子色谱法测定滴眼剂中抑菌剂苯扎氯铵和苯扎溴铵的含量.方法 采用SH-AC-11色谱柱(250 mm×4.6 mm),电导检测器,淋洗液为23 mmol/L氢氧化钾溶液,流速为0.6 ml/min,抑制器电流为56 mA,进样量为25 μl.结果 苯扎氯铵和苯扎溴铵分别在1.25~62.50 μg/ml和1.02~51.00 μg/ml范围内线性关系良好(r分别为0.9997和0.9998),加样回收率分别为100.6%(RSD=1.7%)和100.4%(RSD=1.6%).结论 该方法准确性高,专属性强,可用于滴眼剂中抑菌剂苯扎氯铵和苯扎溴铵的质量控制.

Abstract

Objective To determine the contents of benzalkonium chloride and benzalkonium bromide as bacteriostatic agents in eye drops by ion chromatography.Methods The assay was performed on SH-AC-11 column(250 mmx4 mm)by conductivity detector,the eluent was 23 mmol/L potassium hydroxide solution with the flow rate of 0.6 ml/min,the suppressor current was 56 mA,and the sample injection volume was 25 μl.Results Benzalkonium chloride presented a good linearity between peak area and concentration in the range of 1.25-62.50 μg/ml(r=0.9997)with the average recovery of 100.6%(RSD=1.7%),and benzalkonium bromide presented a good linearity in the range of 1.02-51.00 μg/ml(r=0.9998)with the average recovery of 100.4%(RSD=1.6%).Conclusion This method has high accuracy and strong specificity,and can be used for the quality control of benzalkonium chloride and benzalkonium bromide in eye drops.

关键词

滴眼剂/抑菌剂/离子色谱/苯扎氯铵/苯扎溴铵/质量控制

Key words

eye drops/bacteriostatic agent/ion chromatography/benzalkonium chloride/benzalkonium bromide/quality control

引用本文复制引用

基金项目

滨州市农社领域科技创新政策引导计划项目(2022SHFZ043)

出版年

2024
食品与药品
山东省生物药物研究院

食品与药品

CSTPCD
影响因子:0.537
ISSN:1672-979X
参考文献量9
段落导航相关论文