Cause analysis and countermeasures for increasing water content of lean methanol in low-temperature methanol washing system of synthetic ammonia unit
In response to the abnormal increase(up to 2.6%)in the water content of lean methanol(mass fraction,the same below)in the low-temper-ature methanol washing system of the 300 kt/a syn-thetic ammonia unit of Jilin Petrochemical Company of PetroChina after the process transformation of the newly added synthetic gas purification system,which exceeded the design index value(1.5%)and had to be operated at reduced-load,the relevant influenc-ing factors were analyzed and investigated,and the reasons leading to the blockage of the sieve holes of the methanol/water separation tower tray were ana-lyzed,then the corresponding process optimization measures were implemented.The results showed that after the implementation of process optimization measures,the separation effect of methanol/water separation from the tower was significantly improved.Not only did it increase the load rate of the low-tem-perature methanol washing system from 82%to 100%,but also reduced the water content of lean methanol to 0.4%.