首页|自动电位滴定法测定白酒中酸酯总量的不确定度评定

自动电位滴定法测定白酒中酸酯总量的不确定度评定

扫码查看
依据《测量不确定度评定和表示》(JJF 10591.1-2012)和《白酒分析方法》(GB/T 10345-2022),采用自动电位滴定法测定白酒中的酸酯总量,并建立数学模型对白酒测定过程中引入的不确定度进行分析和评定.结果表明,白酒中的酸酯总量为(55.7±0.6)mmol·L-1(k=2);总酸、总酯分别消耗标准滴定溶液的体积所引入的不确定度分量贡献最大,酒样重复性测定和标准滴定溶液浓度所引入的不确定度分量贡献次之,而引入不确定度分量贡献最小的是酒样移取体积.
Evaluation of Uncertainty in the Measurement of Total Acid and Ester in Baijiu by Automatic Potentiometric Titration
According to JJF 10591.1-2012 and GB/T 10345-2022,the total amount of acid and ester in Baijiu was determined by automatic potentiometric titration,and the uncertainty introduced in the determination of Baijiu was analyzed and evaluated by establishing a mathematical model.The results showed that the total amount of acid and ester in Baijiu was(55.7±0.6)mmol·L-1(k=2).The uncertainty component of total acid and total ester consumed by the volume of standard titration solution contributed the most.The uncertainty components introduced by the repeatability measurement of Baijiu samples and the concentration of standard titration solutions were secondary.The smallest contribution of introducing uncertainty components was the removal volume of Baijiu sample.

automatic potentiometric titrationBaijiutotal amount of acid and esteruncertainty

陈益超、麻春华、顾振昆、田甜、毛健

展开 >

湘西土家族苗族自治州质量检验及计量检定中心,湖南吉首 416000

粮食发酵与食品生物制造国家工程研究中心(江南大学),江苏无锡 214122

自动电位滴定法 白酒 酸酯总量 不确定度

2024

食品安全导刊
商业科技质量中心 北京肉类食品协会

食品安全导刊

影响因子:0.065
ISSN:1674-0270
年,卷(期):2024.(14)