首页|乳腺癌患者病理类型与超声BI-RADS分级、声像图表现的关系分析

乳腺癌患者病理类型与超声BI-RADS分级、声像图表现的关系分析

扫码查看
目的 分析乳腺癌患者超声乳腺影像报告和数据系统(BI-RADS)分级、声像图表现与病理类型的关系.方法 回顾性分析87例乳腺包块患者(87个包块)的有关资料,所有患者均行超声检查,并行BI-RADS分级,穿刺活检或术后病理检查证实包块性质,统计分析超声诊断与病理检查结果.结果 超声BI-RADS分级显示,87例包块患者中,共检出49例恶性病变(4a级、4b级、4c级、5级),38例良性病变(3级).病理检查结果显示,87例乳腺包块患者共检出87个包块,其中恶性病变共50例,主要包括浸润性导管癌31例,导管原位癌12例,浸润性微乳头状癌7例;良性病变共37例,主要包括乳腺增生结节23例,纤维腺瘤12例,其他2例.以病理检查为"金标准",超声BI-RADS分级检查的灵敏度为96.00%(48/50)、特异度为97.30%(36/37)、准确度为96.55%(84/87);kappa检验显示:超声BI-RADS分级检查结果与病理检查结果的一致性极好(kappa值=0.930,P=0.000);恶性病变直径≥2 cm、钙化、边界不清、纵横比≥1、后方回声逐渐衰减、血流(PSV>20 cm/s,RI>0.70)的占比均高于良性病变,差异有统计学意义(P<0.05).结论 超声BI-RADS分级与声像图表现结合应用,可提高乳腺包块的定性诊断,精准地判定乳腺包块的良恶性,进而提高乳腺癌的检出准确性,为临床提供可靠的依据.
Analysis of the Relationship Between Pathological Types,Ultrasound BI-RADS Grades and Ultrasonographic Manifestations in Breast Cancer Patients
Objective To analyze the relationship between the grading of BI-RADS,sonographic findings and pathologi-cal types in breast cancer patients.Methods A retrospective analysis was conducted on the relevant data of 87 patients with breast masses(87 masses).All patients underwent ultrasound examination,and BI-RADS grading was performed.The nature of the masses was confirmed by puncture biopsy or postoperative pathological examination.The ultrasound diagnosis and pathological examination results were statistically analyzed.Results The ultrasound BI-RADS grading showed that out of 87 patients with masses,a total of 49 malignant lesions(grade 4a,4b,4c,and 5)and 38 benign lesions(grade 3)were detected.The pathological examination results showed that a total of 87 breast mass patients were detected,including 50 cases of malignant lesions,mainly including 31 cases of invasive ductal carcinoma,12 cases of ductal carcinoma in situ,and 7 cases of invasive micropapillary carci-noma;There were 37 cases of benign lesions,mainly including 23 cases of breast hyperplasia nodules,12 cases of fibroadenomas,and 2 cases of others.Using pathological examination as the"gold standard",the sensitivity of ultrasound BI-RADS grading exam-ination was 96.00%(48/50),specificity was 97.30%(36/37),and accuracy was 96.55%(84/87);The kappa test showed that the consistency between the ultrasound BI-RADS grading test results and the pathological examination results was excellent(kappa value=0.930,P=0.000);The proportion of malignant lesions with a diameter ≥2 cm,calcification,unclear boundaries,aspect ratio ≥1,gradual attenuation of posterior echo,and blood flow(PSV>20 cm/s,RI>0.70)was higher than that of benign le-sions,and the difference was statistically significant(P<0.05).Conclusion The combination of ultrasound BI-RADS grading and sonography can improve the qualitative diagnosis of breast masses,accurately determine the benign and malignant breast mas-ses,and then improve the detection accuracy of breast cancer,providing reliable basis for clinical practice.

Breast cancerPathological classificationBreast imaging reporting and data systemSonographic representa-tion

刘亚君

展开 >

475000 河南省开封市妇产医院

乳腺癌 病理分型 乳腺影像报告和数据系统 声像图表现

2024

实用癌症杂志
江西省肿瘤医院 江西省肿瘤研究所

实用癌症杂志

影响因子:1.241
ISSN:1001-5930
年,卷(期):2024.39(8)